Cutmaster 12mm – Tweco CutMaster 12mm User Manual
Page 54

CUTMASTER 12mm
5-8
SERVICE
Manual 0-5076
3. Loosen the two bolts on the top of the Filter Assembly
enough to allow the Filter Elements to move freely.
4. Note the location and orientation of the old Filter Ele-
ments.
5. Slide out the old Filter Elements.
First & Second
Stage
Cartridges
(as marked)
Art # A-02942
Optional Two-Stage Filter Replacement
6. Slide the replacement Filter Elements into the Filter
Assembly, with the same orientation as noted in Step
4 above.
7. Hand tighten the two bolts evenly, then torque each
bolt to 20 - 30 in-lbs (2.3 - 3.4 Nm). Improper torque
may damage the gasket.
8. Slowly apply air pressure to the assembly, checking
for leaks.
NOTE
A small amount of air leakage from the bottom
fitting is normal.
This completes the parts replacement procedures.