Cutmaster 39 – Tweco 39 CutMaster User Manual

Page 30

Advertising
background image

cutmaster 39

OPERATION

4-2

Manual 0-4975

B. Control Panel

A-07931

3

1

4
5

6

2

A

30

20

26

28

24

22

7

1. ON / OFF Switch

Controls input power to the power supply. Up is ON, down is OFF.

2. RUN / SET Switch

RUN (up) position is for general torch operation. SET (down) position is for setting gas pressure and purging

lines.

3. (A) Output Current Control

Sets the desired output current. If the overload protection (fuse or circuit breaker) on the input power circuit

opens frequently, either reduce cutting output, reduce the cutting time, or connect the unit to more adequate

input power. Refer to Section 2 for input power requirements.

4.

AC Indicator

Steady light indicates power supply is ready for operation. Blinking light indicates unit is in protective in-

terlock mode. Shut unit off, shut off or disconnect input power, correct the fault, and restart the unit. Refer to

Section 5 for details.

5. TEMP Indicator

Indicator is normally OFF. Indicator is ON when internal temperature exceeds normal limits. Allow the unit

to run with the fan on until the Temp indicator turns off.

6.

GAS Indicator

Indicator is ON when adequate input gas pressure is present to operate the power supply.

7.

DC Indicator

Indicator is ON when DC output circuit is active.

Advertising