SERVICE

B. AC indicator

OFF

1. Switch at customer's main power panel in OFF (open)

position.

a. Close main power switch.

2. Power Supply ON / OFF switch in OFF position.

a. Turn switch to ON.

3. Customer's main power line fuse(s) or circuit

breaker(s) blown

a. Check main power panel fuse(s) and replace

as required.

4. Actual input voltage does not correspond to voltage of

unit

a. Verify that the input line voltage is correct. Re-

fer to Section 2, Input Wiring Requirements.

5. Faulty components in unit

a. Return for repair or have qualified technician

repair per Service Manual.

C. AC indicator

flashing; Torch cannot be

activated

1. System is in protective interlock mode. (User held

torch trigger while turning on ON / OFF switch.)

a. Release torch trigger, set ON / OFF switch to

OFF (down). Return ON / OFF switch to ON

(up) position.

2. System is in protective interlock mode. (Torch parts

are missing or loose.)

a. Release torch trigger, and set ON / OFF

switch to OFF (down). Open main disconnect

switch. Check torch parts, including O - rings

on torch head. Refer to illustration on page 5

- 1. Replace parts as needed. Reinstall shield

cup; hand - tighten it securely against the torch

head. Close main disconnect switch. Set ON

/ OFF switch to ON (up) position.

3. System is in protective interlock mode. (User removed

shield cup from torch while power supply ON / OFF
switch was ON.)

a. Release torch trigger, and set ON / OFF switch

to OFF (down). Set ON / OFF switch to ON

(up).

D. Torch will not pilot; DC indicator

and GAS

indicator flash alternately when torch trigger
is activated

1. Gas pressure is too low. Adjust gas pressure to 65 psi

/ 4.5 bar.

E. AC indicator

flashing; Temp indicator

ON

1. Fan disconnected or blocked.

a. Clear fan if blocked; let power supply cool.

F. AC indicator ON; TEMP indicator ON

1. Air flow blocked

a. Check for blocked air flow around the unit

and correct condition.

2. Fan blocked

a. Check and correct condition.

3. Unit is overheated

a. Let unit cool down for at least 5 minutes.

Make sure the unit has not been operated

beyond Duty Cycle limit. Refer to duty cycle

data in Section 2.

4. Input line voltage is below 100 Volts

a. Check and connect to proper input power

line.

5. Faulty components in unit

a. Return for repair or have qualified technician

repair per Service Manual.

G. Torch will not pilot when torch switch is activat-

ed

1. System is in SET mode

a. Change to RUN mode.

2. Upper O-ring on torch head is in wrong position.

a. Remove shield cup from torch; check position

of upper O-ring. Correct if necessary.

Lower O-Ring

Upper O-Ring
in Correct Groove

Upper Groove
with Vent Holes
Must Remain Open

Threads