Section 5 torch:service, 5t.01 general maintenance, Section 5 torch:service t-1 – Tweco 39 CutMaster User Manual

Page 55: 5t.01 general maintenance t-1, Cutmaster 39

Advertising
background image

cutmaster 39

Manual 0-4975

5T-1

SERVICE

SECTION 5 TORCH:

SERVICE

5T.01 General Maintenance

NOTE

Refer to Previous "Section 5 System" for common
and fault indicator descriptions.

Cleaning Torch

Even if precautions are taken to use only clean air

with a torch, eventually the inside of the torch be-

comes coated with residue. This buildup can affect

the pilot arc initiation and the overall cut quality of

the torch.

WARNINGS

Disconnect primary power to the system before
disassembling the torch or torch leads.

DO NOT touch any internal torch parts while the
AC indicator light of the Power Supply is ON.

The inside of the torch should be cleaned with electri-

cal contact cleaner using a cotton swab or soft wet

rag. In severe cases, the torch can be removed from

the leads and cleaned more thoroughly by pouring

electrical contact cleaner into the torch and blowing

it through with compressed air.

CAUTION

Dry the torch thoroughly before reinstalling.

O-Ring Lubrication

An o-ring on the Torch ATC Male Connector requires

lubrication on a scheduled basis. This will allow the

o-ring to remain pliable and provide a proper seal.

The o-ring will dry out, becoming hard and cracked,

if the o-ring lubricant is not used on a regular basis.

This can lead to potential performance problems.

It is recommended to apply a very light film of o-

ring lubricant (Catalog # 8-4025) to the o-ring on a

weekly basis.

NOTE

DO NOT use other lubricants or grease, they may
not be designed to operate within high tempera-
tures or may contain “unknown elements” that
may react with the atmosphere. This reaction
can leave contaminants inside the torch. Either
of these conditions can lead to inconsistent per-
formance or poor parts life.

ATC Male Connector

Art #A-03791

Gas Fitting

O-Ring