5. Torch consumables worn

a. Check torch shield cup, tip, starter element,

and electrode; replace as needed.

6. Faulty components in unit

a. Return for repair or have qualified technician

repair per Service Manual.

N. No gas flow; AC indicator

ON; Fan oper-

ates

1. Gas not connected or pressure too low

a. Check gas connections. Adjust gas pressure

to proper setting.

2. Shield Cup not properly installed.

a. Check to see that Shield Cup is properly in-

stalled.

3. Faulty components in unit

a. Return for repair or have qualified technician

repair.

O. Torch cuts but not adequately

1. Current

(A) control set too low

a. Increase current setting.

2. Torch is being moved too fast across workpiece

a. Reduce cutting speed.

3. Excessive oil or moisture in torch

a. Hold torch 1/8 inch (3 mm) from clean surface

while purging and observe oil or moisture

buildup (do not activate torch). If there are

contaminants in the gas, additional filtering

may be needed.