INTRODUCTION & DESCRIPTION

10

Manual 0-2557

9. Plasma Gas Requirements

a. Plasma Gas

Compressed Air, Oxygen (O2), Nitrogen (N2),
or Argon/Hydrogen(ArH2)

b. Pressure

60 psi (3.4 bar)

CAUTION

Maximum input gas pressure must not exceed 125
psi (8.6 BAR)

c. Hot Flow

Cutting: 22 - 28 scfh (10.4 - 13.2 lpm)

Gouging: 22 - 43 scfh (10.4 - 20.3 lpm)

NOTE

Hot flow is measured with the main arc activated.
When pressure is set correctly the plasma gas flow
rate is significantly higher until the arc is initi-
ated.

10. Secondary Gas Requirements

a. Secondary Gas

Compressed Air, Carbon Dioxide (CO2), or Ni-
trogen (N2)

b. Pressure

60 psi (3.4 bar)

CAUTION

Maximum input gas pressure must not exceed 125
psi (8.6 BAR)

c. Flow

Cutting or Gouging: 220 scfh (103 lpm)

CAUTION

Secondary water source only for use in machine
applications (refer to Power Base Unit Operating
Manual 0-2474).

11. Secondary Water Requirements

a. Water Source

Tap Water

b. Water Pressure

Min. 50 psi (3.5 BAR)

c. Water Flow

Cutting: 8 gph (30.3 lph)

12. Weight (without leads)

1.0 lb (.45 kg)

13. Torch Dimensions

Min. 6.750 in (171.5 mm)

Max. 11.125 in (282.6 mm)

1.937 in

(49.2 mm)

1.38 in

(35 mm)

17.350 in

(441 mm)

1.875 in

(47.6 mm)

1.531 in

(38.9 mm)

0.718 in

(18.2 mm)

A-01023

Figure 2-2 Torch Dimensions

B. Torch Leads Extension

NOTE

The following applies to the Torch Leads Exten-
sion used in the TD-750 System only.

Part of the TD-750 Systems to interface the Power Base
Module to the Arc Starter Box. Supplied in 50 ft (15.2
m) length. Accessories available to extend the Arc
Starter Box from the Power Base Module up to 100 ft
(30.5 m).

2.04 Options And Accessories

These items can be used to customize a standard system
for a particular application or to further enhance perfor-
mance (refer to Section 6 for ordering information).

• Phenolic (plastic) Pinch Block Mounting Assembly

For machine mounted torch applications where a
non-metal mounting assembly is desired.

• Multi-Gas Conversion Kits

Converts dual gas air/air systems to multi-gas op-
eration. The multi-gas systems can use oxygen, ni-
trogen, or argon/hydrogen as the plasma gas. The
kits include regulators, supply hoses, and spare
parts kit.