Appendix i: sequence of operation block diagram – Tweco Max 300 w-TD-750 User Manual

Page 49

Advertising
background image

Manual 0-2557

43

APPENDIX

APPENDIX I: SEQUENCE OF OPERATION BLOCK

DIAGRAM

ACTION

ON/OFF switch

to OFF

RESULT

All indicators off.

ACTION

RUN/SET switch

to RUN.

RESULT

Gas flow stops.

GAS indicator off.

Power circuit ready.

Fan off.

ACTION

Torch moved within

transfer distance of workpiece.

RESULT

Main arc transfer.

Pilot arc off.

PILOT indicator off.

DC indicator still on.

ACTION

Torch deactivated (by torch switch

release or by remote device).

RESULT

Main arc stops. Pilot stops.

(Power supply enable signal removed.)

DC indicator off.

PILOT indicator off.

NOTE - If torch is activated during

post-flow, pilot arc will immediately restart.
If torch is within transfer distance (3/8 in) of

workpiece, main arc will transfer.

After post-flow:

Gas solenoid closes, gas flow stops.

GAS indicator off.

Fan off.

ACTION

Open external

disconnect.

RESULT

No power to system.

ACTION

Close external

disconnect switch.

RESULT

Power to system.

ACTION

RUN/SET switch

to SET.

RESULT

Gas solenoid open,

gas flows to set pressure.

GAS indicator on.

Fan on.

ACTION

Torch moved away

from work (while

still activated).

RESULT

Main arc stops.

Pilot arc auto-

matically restarts.

PILOT indicator on.

PILOT ARC

ACTION

ON/OFF switch

to ON.

RESULT

AC, TEMP, PIP

indicators on.

Pilot disabled during

pre-flow.

ACTION

Protect eyes and

activate torch

RESULT

Gas flows

GAS indicator on

Fan on

After gas pre-flow:

DC indicator on.

Power supply enabled.

HF relay closes.

Pilot arc established

PILOT indicator on.

A-00356