SPECIFICATIONS

Gas Requirements

The customer will provide all gases and pressure regulators. Gases must be of high quality. Pressure regulators
shall be double stage.

Gas

Quality

Minimum Pressure

Flow

O

2

(Oxygen)

99.5% Purity

(Liquid recommended)

120 psi

8.3 bar / 827 kPa

70 scfh (1982 l/h)

N

2

(Nitrogen)

99.5% Purity

(Liquid recommended)

<1000 ppm O

2

, <32

ppm H

2

O)

120 psi

8.3 bar / 827 kPa

204 scfh (5777 l/h)

Compressed

or Bottled Air

Clean, Dry,

Free of Oil (see Note 1)

120 psi

8.3 bar / 827 kPa

244 scfh (6910 l/h)

H35 (Argon-Hydrogen)
H35 = 35% Hydrogen,

65% Argon

99.995% Purity

(gas recommended)

120 psi

8.3 bar / 827 kPa

90 scfh (2550 l/h)

H

2

O (Water)

See Note 2

50 psi (3.5 bar)

10 gph (38 lph)

Note 3: Water Pressure Regulator No. 8-6118 is recommended to ensure proper water pressure.

Ultra-Cut 150 Power Supply: Gas Pressures, Flows, and Quality Requirements

Note 2: The tap water source does not need to be deionized, but in water systems with extremely
high mineral content a water softener is recommended. Tap water with high levels of particulate
matter must be filtered.

Note 1: The air source must be adequately filtered to remove all oil or grease. Oil or grease
contamination from compressed or bottled air can cause fires in conjunction with oxygen.

For filtering, a coalescing filter able to filter to 0.01 microns should be placed as close as
possible to the gas inlets on the Gas Control Module.

Gas Applications

MATERIAL

PREFLOW PLASMA SHIELD PREFLOW PLASMA SHIELD PREFLOW PLASMA SHIELD

Air

Air

Air

Air

Air

Air

N

2

N

2

H

2

0

N

2

N

2

H

2

0

Air

Air

Air

Air

Air

Air

N

2

N

2

H

2

0

N

2

N

2

H

2

0

Air

Air

Air

Air

Air

Air

N

2

N

2

H

2

0

N

2

N

2

H

2

0

85A CUT

Air

Air

Air

N

2

H

35

N

2

N

2

H

35

N

2

N

2

N

2

H

2

0

N

2

N

2

H

2

0

N

2

H

35

N

2

N

2

H

35

N

2

N

2

N

2

H

2

0

N

2

N

2

H

2

0

OPERATION

30A CUT

70 A CUT

100 A CUT

50 A CUT

O

2

Air

O

2

O

2

Air

Air

Air

GAS TYPE

GAS TYPE

GAS TYPE

Air

O

2

Air

O

2

Air

Ultra-Cut-150 Gas Applications

MILD STEEL

STAINLESS STEEL

ALUMINUM

Air

O

2

Air

150A CUT

Advertising