T. complete the installation – Tweco 150 Ultra-Cut User Manual

Page 63

Advertising
background image

Manual No. 0-4800

3-41

INSTALLATION

Torch Head O-Ring

Torch Head

Art # A-07202

0.063 - 0.083"
(1.6 - 2.1 mm)

Protrusion

Installing Assembled Cartridge Onto Torch Head

6. Slide the ohmic clip over the shield cup if using ohmic torch height sensing.

A-03393

Ohmic Clip

7. Connect the wire lead from the height finder to the ohmic clip if using ohmic torch height sensing.

NOTE

Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the
ohmic sensing circuit.

T.

Complete the Installation

1. Remove the cap from the coolant tank. Fill the coolant tank to the level shown, with Thermal Dynamics

coolant. The coolant level is visible through the translucent coolant tank. The amount of coolant required
varies with torch leads length.

Cat. Number and Mixture

Mixture

Protects To

7-3580 'Extra-Cool

TM

'

25 / 75

10° F / -12° C

7-3581 'Ultra-Cool

TM

'

50 / 50

27° F / -33° C

7-3582 'Extreme Cool

T M

'

Concentrate*

-65° F / -51° C

Coolant Capabilities

* For mixing with D-I Cool

TM

7-3583

Advertising