Auto-cut 300 xt – Tweco 300 XT Auto-Cut 400V User Manual
Page 36
AUTO-CUT 300 XT
3-12
INSTALLATION
Manual 0-5290
CAUTION
Printed circuit boards in the Command-Control Module are static sensitive. Discharge any built-up static charges
in your body or surroundings before touching the printed circuit boards.
SW-6: OK-to-Move: Contact closure, 120VAC @ 1A (Factory default setting) or
DC Volts (16-18vdc@ up to 100 ma.)
SW-11: Set “B” position, (up) for default
SW-11: Set “A” position (down) for remote analog current control. SW-8-2 must be set to “ON”.
SW-12-1/2/3/4: Divided Arc signal All = OFF = 50:1 (Factory default setting)
1 = ON = 16.6:1
2 = ON = 30:1
3 = ON = 40:1
4 = ON = 25:1
Art # A-11912_AB
Only 1 on at a time.
SW13: Auto-Cut XT Switch positions, off
SW13 (Note positions 3-4 are not yet used)
1
2
3
4
SW13
SW6
SW12
ON
SW11