CAUTION

Printed circuit boards in the Command-Control Module are static sensitive. Discharge any built-up static charges
in your body or surroundings before touching the printed circuit boards.

SW-6: OK-to-Move: Contact closure, 120VAC @ 1A (Factory default setting) or
DC Volts (16-18vdc@ up to 100 ma.)
SW-11: Set “B” position, (up) for default
SW-11: Set “A” position (down) for remote analog current control. SW-8-2 must be set to “ON”.

SW-12-1/2/3/4: Divided Arc signal All = OFF = 50:1 (Factory default setting)

1 = ON = 16.6:1
2 = ON = 30:1
3 = ON = 40:1
4 = ON = 25:1

Art # A-11912_AB

Only 1 on at a time.

SW13: Auto-Cut XT Switch positions, off

SW13 (Note positions 3-4 are not yet used)

1

2

3

4

SW13