Auto-cut 300 xt – Tweco 300 XT Auto-Cut 400V User Manual

Page 58

Advertising
background image

AUTO-CUT 300 XT

4-10

OPERATION

Manual 0-5290

Code

Message

Remedy / Comments

267

Inverter 2A No Input
Power

Inverter section may have no input power. Contactor W1 not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.

268

Inverter 2B No Input
Power

Inverter section may have no input power. Contactor W2 not closed; Defective contactor or
CB4 tripped; Inverter section input not connected; Defective Inverter.

269

Inverter 3A No Input
Power

Inverter section may have no input power. Contactor W2 not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.

270

Inverter 3B No Input
Power

Inverter section may have no input power. Contactor W2 not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.

271

Inverter ID reading
fault

CCM found ID values inconsistant during reading. CCM to an Inverter section ribbon damaged
or disconnected; Inproper ribbon cable routing.

CCM Status Code

Group 3 -- Gas Controller Status & Protocol

Code

Message

Remedy / Comments

301

Not used

Reserved for other models.

302

Reserved

No information available; Contact customer service

303

Gas Supply Pressure
out of range.

Autocut is in SET mode or Plasma gas pressure is too low; Defective gas pressure sensor
(PS1).

304

Gas Control Purging

Normal following power up or returning from Plasma Disable.

305

Not used

Reserved for other models.

306

Not used

Reserved for other future use.

307

Not used

Reserved for other models.

308

Gas Control Type
Mismatch

Wrong CCM, must be Auto-cut type.

309

Not used

Reserved for other models.

310

Not used

Reserved for other models.

311

Not used

Reserved for other models.

312

Not used

Reserved for other models.

313

Not used

Reserved for other models.

Advertising