225

Inverter 1A Incom-

patible Revision

Unsupported Inverter Revision; Ribbon cable CCM J31 to Inverter Module 1 Section A dam-

aged; CCM code version incompatible with Inverter revision or model

226

Inverter 1B Incom-

patible Revision

Unsupported Inverter Revision; Ribbon cable CCM J32 to Inverter Module 1 Section B dam-

aged ; CCM code version incompatible with Inverter revision or model

227

Inverter 2A Incom-

patible Revision

Unsupported Inverter Revision; Ribbon cable CCM J33 to Inverter Module 2 Section A dam-

aged; CCM code version incompatible with Inverter revision or model

228

Not used

Reserved for other model with another inverter section

229

Inverter 3A Incom-

patible Revision

Unsupported Inverter Revision; Ribbon cable CCM J35 to Inverter Module 3 Section A dam-

aged ; CCM code version incompatible with Inverter revision or model

230

Inverter 3B Incom-

patible Revision

Unsupported Inverter Revision; Ribbon cable CCM J36 to Inverter Module 3 Section B dam-

aged ; CCM code version incompatible with Inverter revision or model

231

Inverter 1A VAC

Mismatch

Inverter AC Voltage rating incompatible with Power Supply voltage rating; Ribbon cable

CCM J31 to Inverter Module 1 Section B damaged or loose; Wrong voltage Inverter Module 1

installed; Defective Inverter module

232

Inverter 1B VAC

Mismatch

Inverter AC Voltage rating incompatible with Power Supply voltage rating; Ribbon cable

CCM J32 to Inverter Module 1 Section B damaged or loose; Wrong voltage Inverter Module 1

installed; Defective Inverter module

233

Inverter 2A VAC

Mismatch

Inverter AC Voltage rating incompatible with Power Supply voltage rating; Ribbon cable

CCM J33 to Inverter Module 2 Section A damaged or loose; Wrong voltage Inverter Module 2

installed; Defective Inverter module

234

Not used

Reserved for other model with another inverter section

235

Inverter 3A VAC

Mismatch

Inverter AC Voltage rating incompatible with Power Supply voltage rating; Ribbon cable

CCM J35 to Inverter Module 3 Section A damaged or loose; Wrong voltage Inverter Module 2

installed; Defective Inverter module

236

Inverter 3B VAC

Mismatch

Inverter AC Voltage rating incompatible with Power Supply voltage rating; Ribbon cable

CCM J36 to Inverter Module 3 Section B damaged or loose; Wrong voltage Inverter Module 3

installed; Defective Inverter module

237

Too Few Inverters

Found

Two or more Inverter Sections required to operate; Ribbon cable from CCM to Inverter Section

damaged or disconnected;

238

BIAS VAC Invalid

Invalid AC Voltage Selection; Damaged or loose connection at J61 of System Bias Supply

239

AC Voltage High

System Bias PCB detected AC Voltage is higher than Power Supply rated Voltage; System

Bias Supply J61 Voltage Selection connection damaged or disconnected; Defective System

Bias PCB; Defective CCM

240

AC Voltage Low

System Bias PCB detected AC Voltage is lower than Power Supply rated Voltage; System

Bias Supply J61 Voltage Selection connection damaged or disconnected; Defective System

Bias PCB; Defective CCM

241

Inverter 1A Input

Voltage Error

Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of Inverter

Module 1 Section A; Poor AC Power Quality; Defective W1 contactor; Loose or open connec-

tion between input terminals and W1 contactor or contactor and input of Inverter Section;

Defective Inverter module

242

Inverter 1B Input

Voltage Error

Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of Inverter

Module 1 Section B; Poor AC Power Quality; Defective W1 contactor; Loose or open connec-

tion between input terminals and W1 contactor or contactor and input of Inverter Section;

Defective Inverter module

243

Inverter 2A Input

Voltage Error

Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of Inverter

Module 2 Section A; Poor AC Power Quality; Defective W1 contactor; Loose or open connec-

tion between input terminals and W1 contactor or contactor and input of Inverter Section;

Defective Inverter module