Auto-cut 300 xt – Tweco 300 XT Auto-Cut 400V User Manual

Page 57

Advertising
background image

AUTO-CUT 300 XT

Manual 0-5290

OPERATION

4-9

Code

Message

Remedy / Comments

244

Not used

Reserved for other model with another inverter section

245

Inverter 3A Input
Voltage Error

Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of Inverter
Module 3 Section A; Poor AC Power Quality; Defective W2 contactor; Loose or open connec-
tion between input terminals and W2 contactor or contactor and input of Inverter Section;
Defective Inverter module

246

Inverter 3B Input
Voltage Error

Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of Inverter
Module 3 Section B; Poor AC Power Quality; Defective W2 contactor; Loose or open connec-
tion between input terminals and W2 contactor or contactor and input of Inverter Section;
Defective Inverter module

247

Inverter 1A Circuit
Fault

Inverter Module 1 Section A detected a circuit fault; Damaged Inverter Module 1

248

Inverter 1B Circuit
Fault

Inverter Module 1 Section B detected a circuit fault; Damaged Inverter Module 1

249

Inverter 2A Circuit
Fault

Inverter Module 2 Section A detected a circuit fault; Damaged Inverter Module 2

250

Not used

Reserved for other model with another inverter section

251

Inverter 3A Circuit
Fault

Inverter Module 3 Section A detected a circuit fault; Damaged Inverter Module 3

252

Inverter 3B Circuit
Fault

Inverter Module 3 Section B detected a circuit fault; Damaged Inverter Module 3

253

Inverter 1A Over
Temp Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.

254

Inverter 1B Over
Temp Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.

255

Inverter 2A Over
Temp Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.

256

Not used

Reserved for other model with another inverter section

257

Inverter 3A Over
Temp Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.

258

Inverter 3B Over
Temp Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.

259

Inverter 1A No Input
Power

Inverter section may have no input power. Contactor not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.

260

Inverter 1B No Input
Power

Inverter section may have no input power. Contactor not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.

261

Inverter 2A Over
Temp Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.

262

Inverter 2B Over
Temp Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.

263

Inverter 3A Over
Temp Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.

264

Inverter 3B Over
Temp Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce
power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.

265

Inverter 1A No Input
Power

Inverter section may have no input power. Contactor W1 not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.

266

Inverter 1B No Input
Power

Inverter section may have no input power. Contactor W1 not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.