The Status Indicator flashes a 2 part code that indicates the status of the system.

When the Status Indicator is dark the system is ready to cut. It is normal for the Status Indicator

to flash when the GCM mode switch is placed in set mode. At system start up, the Status

Indicator flashes a 2 part code to indicate the CCM firmware version that is loaded into the

system. This code appears only once at start up. During normal operation the Status Indicator

may flash a code indicating an error or a condition that should be corrected. Some codes will

cause the system to cease operation to prevent damage to the hardware. Other codes will not

cause the system to cease operation, but will continue until the condition which caused the code

to initiate is changed.

Status codes appear in a 2 part sequence. The Status Indicator will flash a number of

times to indicate the first number in the code sequence, then pause for 1.2 seconds and flash

the second number of the code. After 4 seconds, the code sequence will repeat.

Example: The Status Indicator blinks 4 times, pauses, then blinks 3 times.

This code (4-3) indicates overheating coolant and will continue until the condition is corrected.

Status Indicator Codes

Fault Code Key

Error

Code

Error

Remedy / Comments

1-1

System not Enabled or
Missing AC Input Phase

Plasma Enable Off ; External E-Stop Activated or
CCM TB1-1&2 jumper missing; Missing AC Phase;
No power to GCM 2000 or 2010 Gas Control,
check GCM control cable connected, reset CP4
or CP5 circuit breaker in power supply, blown fuse
F19 in GCM.

1-2

Pilot Ignition Failure

Pilot did not start within 15 seconds.
Preflow pressure too high; Defective Arc Starter

1-3

Lost Pilot

Pilot went out without shutoff signal; Preflow
pressure too high; cut current set too low for
consumables.

1-4

Loss of Transfer

Arc transfer (>50 ms.) then arc lost with START still
on. Standoff too high; Current set too low.

1-5

Off the Plate

Function not currently enabled

1-6

Pilot Timed out w/o
Transfer

Must transfer from Pilot to Cutting Arc in 85 ms.
(SW8-1 OFF) or 3 sec. (SW8-1 ON). Standoff too
high or void in work under torch; cut current too low
for consumables; Preflow pressure too low.

1-7

Tip Saver

Function not currently enabled.

1-8

Possible Shorted Torch

Detected tip voltage too close to electrode voltage.
Plasma flow/pressure too low; Plasma leak; cut
current too high; shorted torch body; consumable
parts worn out.