Page 1 – Tweco Dynamics Automation User Manual

Page 21

Advertising
background image

Fault Code Key

Error

Code

Error

Remedy / Comments

5-1

CANBUS Failure to
Acknowledge fault.

If GCM 1000, Basic ID signal missing; Other gas controls,
Fiber disconnected or broken, Transceiver (what fiber plugs
into) fault, replace Gas control PCB or CCM

5-2

CANBUS Off due to
excessive data errors;

Dirt on fiber ends or in connectors, blow out with clean dry
air; fiber not locked into connector; sharp bends in fiber; fiber
defective;

5-3

CANBUS data error
warning. Errors
increasing, will soon
fault.

Dirt on fiber ends or in connectors, blow out with clean dry
air; fiber not locked into connector; sharp bends in fiber; fiber
defective;

5-4

CCM Message not sent

Dirt on fiber ends or in connectors, blow out with clean dry
air; fiber not locked into connector; sharp bends in fiber; fiber
defective; CANBUS hardware error (CCM or Gas Control
PCB)

6-1

CCM Analog
Voltage Error

Replace CCM

6-2

CCM ADC
or DAC error

Replace CCM

6-3

Coolant Flow too High
error, flow > 2.7 gal/min

Torch coolant tube broken or missing; CCM fault, replace
CCM

6-4

CCM Data Memory
error

Replace CCM

page 1