Fault Code Key

Error

Code

Error

Remedy / Comments

2-1

Missing Phase

Blown fuse, Broken or loose connection on power cable

2-2

Wrong input voltage

Inverter(s) not configured correctly for input voltage;
Poor power quality (brownouts, dropouts); Input power capacity
/ wiring too small causing voltage drop; broken or loose power
cable connections.

2-3

Inverter or Pilot
Regulator Over
Temperature

Failed fan; Ambient above 40 deg C. (104 F); Blocked airflow

2-4

Power Supply not
Ready

Defective inverter

2-5

DC Output Low

Output less than 60 VDC; Defective inverter, shorted output;
Shorted pilot regulator (chopper); CCM voltage sense (J6) wire
open or disconnected.

2-6

Primary over current
fault

Over current detected in inverter primary circuit, remove power
to reset; defective inverter; voltage surge;

2-7

Unexpected current

Current >20A in work or pilot leads before pilot ignition; Possible
shorted torch; Defective current sensor.

2-8

Unexpected current
in pilot circuit

Current > 5A in pilot circuit; wrong or mismatched consumables;
Pilot lead shorted to negative in torch tube; Possible shorted
torch

2-9

Unexpected current
in work lead

Current > 5A in work lead; Short to chassis in RAS; Negative
lead short to ground.