INSTALLATION

3-3

E. Connections to Single Phase Input Power

WARNING

Disconnect input power from the power supply

and input cable before attempting this procedure.

These instructions are for changing the input power and or

cable on the 208/230, 400, 460 VAC Power Supply to Single -

Phase input power.

1. Remove the Power Supply cover. See "A.

Cover

Removal".

2. Disconnect the original input power cable from the

main input contactor and the chassis ground connec-

tion.

3. Loosen the through - hole protector on the back panel

of the power supply. Pull the original power cable out

of the power supply.

4. If the power cable being used is not the factory - sup-

plied cable, use a three - conductor input power cable

for the voltage desired and strip back the insulation on

the individual wires.

5. Pass the cable being used through the access opening

in the back panel of the power supply. Refer to Section

"2.04

Power Supply Specifications" for power cable

specifications.

CAUTION

The primary power source and power cable must

conform to local electrical code and the recom-

mended circuit protection and wiring requirements

(refer to table in Section 2).

6. Connect the wires as follows.

• Set Jumper wire and copper bus bar / jumper on

the contactor. See previous illustrations.

• Green / Yellow wire to Ground.

• Remaining wires to L1 and L2 input. It does not

matter what order these wires are attached.

7. With a little slack in the wires, tighten the through - hole

protector to secure the power cable.

8. Reinstall the Power Supply cover. See "B.

Cover

Installation".

9. Connect the opposite end of individual wires to a

customer supplied plug or main disconnect.

10. Connect the input power cable (or close the main

disconnect switch) to supply power.

F. Connections to Three Phase Input Power

WARNING

Disconnect input power from the power supply

and input cable before attempting this procedure.

These instructions are for changing the input power and or

cable on the 208/230, 400, 460 VAC Power Supply to Three -

Phase input power.

1. Remove the Power Supply cover. See "A.

Cover

Removal".

2. Disconnect the original input power cable from the main

input contactor and the chassis ground connection.

3. Loosen the through - hole protector on the back panel

of the power supply. Pull the original power cable out

of the power supply.

4. Using a customer supplied four - conductor input

power cable for the voltage desired, strip back the

insulation on the individual wires.

5. Pass the cable being used through the access opening

in the back panel of the power supply. Refer to Section

"2.04

Power Supply Specifications" for power cable

specifications.

CAUTION

The primary power source and power cable must

conform to local electrical code and the recom-

mended circuit protection and wiring requirements

(refer to table in Section 2).

6. Connect the wires as follows.

• Remove the copper bus bar jumper from L2 and

L3 on the contactor. See previous illustration.

• Green / Yellow wire to Ground.

• Remaining wires to L1, L2 and L3 input. It does

not matter what order these wires are attached.

See the previous illustrations.

7. With a little slack in the wires, tighten the through - hole

protector to secure the power cable.

8. Reinstall the Power Supply cover. See "B.

Cover

Installation".

9. Connect the opposite end of individual wires to a cus-

tomer supplied plug or main disconnect.

10. Connect the input power cable (or close the main

disconnect switch) to supply power.