CUTMASTER A60

Manual 0-4981

INSTALLATION

3T-3

3T.03 Setting Up Automation or Machine Torch

NOTE

An adapter is required to be installed in the power

supply if converting a hand torch system to operate

a machine or automation torch.

WARNING

Disconnect primary power at the source before

disassembling the torch or torch leads.

The Automation and Machine torch include a positioning tube

with rack and pinch block assembly.

1. Mount the torch assembly on the cutting table.

2. To obtain a clean vertical cut, use a square to align the

torch perpendicular to the surface of the workpiece.

Automated and Machine Torch Set - Up

3. The proper torch parts (shield cup, tip, start cartridge,

and electrode) must be installed for the type of op-

eration. Refer to Section "4T.03

Machine and

Hand Torch Parts Selection" for details.