5.04 Fault Indicator

At initial power up, two lights will temporarily illuminate for 2-3

seconds to show the version of software used.

To determine the first digit, count the function indicators left

to right, 1 through 5. To determine the second digit count the

pressure indicators, reading from bottom to top, 0 through 7.

In the example below the Temp indicator and 75 psi indicators

are on indicating the version would be 2.3.

When the

"Fault" indicator is ON or blinking it will be

accompanied by one of the pressure indicator lights de-

pending on what the Fault is. Only one of these faults will

be displayed at one time. If more than one fault exists, when

the first fault is corrected and cleared, the next fault will

then be displayed. It is possible to have a fault indicated

in the function indicators and another fault indicated in the

pressure indicators. The following table shows each of the

Faults possible.

Pressure

Indicator

Fault

Max

Over Pressure

90

Internal Error

85

Shorted Torch

80

Consumables Missing

75

Start Error

70

Parts in Place

65

Input Power

Min

Under Pressure

NOTE

Fault explanations are covered in the following

tables.

Explanation of Faults

UNDER PRESSURE: Indicates that operating pressure is

set too low and power supply output power will be

disabled.

INPUT POWER: Indicates primary line voltage is outside

the operating limits of the power supply as selected

by the setting of INPUT VOLTAGE SELECTION SWITCH

at the rear of the unit. Low is 208/230 VAC and high

is 460 VAC.

PART IN PLACE: Indicates that the shield cup is not prop-

erly installed or tightened.

START ERROR: Indicates that the START SIGNAL was ac-

tive (ie. Torch Trigger depressed, hand held pendant

switch ON or CNC signal for torch ON) during one of

three conditions:

1) During initial power up when ON/OFF switch is

turned to ON position

2) When fault which had been disabling the system

is cleared.

3) When the FUNCTION CONTROL SWITCH Mode is

moved from SET position to any of the other three

(3) modes of operation.

CONSUMABLES MISSING: Indicates that the electrode,

start cartridge or tip is missing or excessively worn.

SHORTED TORCH: Indicates the torch or lead has a shorted

condition between positive and negative leads.

INTERNAL ERROR: Indicates a microprocessor error.

OVER PRESSURE: Indicates that operating pressure is set

too high. The Error Indicator will not flash when the

pressure is above 95 PSI. This LED will remain ON

and the system will operate but pilot starting and cut

performance may be affected.

NOTE

The cooling fans will turn ON as soon as the unit

is turned ON. After the unit is idle for ten (10)

minutes the fans will turn OFF. The fans will come

back ON as soon as the torch switch (Start Signal)

is activated or if the unit is turned OFF, then turned

ON again. If an over temperature condition occurs,

the fans will continue to run while the condition

exists and for a ten (10) minute period once the

condition is cleared.