3.06 Gas Connections

Connecting Gas Supply to Unit

The connection is the same for compressed air or high pressure

cylinders. Refer to the following subsections if an optional air

line filter is to be installed.

1. Connect the air line to the inlet port. The illustration

shows typical fittings as an example.

NOTE

For a secure seal, apply thread sealant to the fitting

threads, according to manufacturer's instructions.

Do not use Teflon tape as a thread sealer, as small

particles of the tape may break off and block the

small air passages in the torch.

Air Connection to Inlet Port

Installing Optional Single - Stage Air Filter

An optional filter kit is recommended for improved filtering with

compressed air, to keep moisture and debris out of the torch.

1. Attach the Single - Stage Filter Hose to the Inlet Port.

2. Attach the Filter Assembly to the filter hose.

3. Connect the air line to the Filter. The illustration shows

typical fittings as an example.

NOTE

For a secure seal, apply thread sealant to the fitting

threads, according to the manufacturer's instruc-

tions. Do Not use Teflon tape as a thread sealer,

as small particles of the tape may break off and

block the small air passages in the torch. Connect

as follows:

Optional Single - Stage Filter Installation

Using High Pressure Air Cylinders

When using high pressure air cylinders as the air supply:

1. Refer to the manufacturer’s specifications for instal-

lation and maintenance procedures for high pressure

regulators.

2. Examine the cylinder valves to be sure they are clean

and free of oil, grease or any foreign material. Briefly

open each cylinder valve to blow out any dust which

may be present.

3. The cylinder must be equipped with an adjustable high

- pressure regulator capable of outlet pressures up to

100 psi (6.9 bar) maximum and flows of at least 300

scfh (141.5 lpm).

4. Connect supply hose to the cylinder.

NOTE

Pressure should be set at 100 psi (6.9 bar) at the

high pressure cylinder regulator.

Supply hose must be at least 1/4 inch (6 mm) I.D.

For a secure seal, apply thread sealant to the fitting

threads, according to manufacturer's instructions.

Do Not use Teflon tape as a thread sealer, as small

particles of the tape may break off and block the

small air passages in the torch.

Installing Optional Two - Stage Air Filter Kit

This optional two - stage air line filter is also for use on

compressed air shop systems. Filter removes moisture and

contaminants to at least 5 microns.

Connect the air supply as follows: