4-2
4. Using a ½”-13 x 1” hex head bolt, position the bolt down so that its threads run
through the crimped lug of the DC Welding Power Cable and through the Power and
Air Connector on the Swivel Cable Assembly. The head of the bolt should be against
the flat side of the crimped lug as shown in Figure 4-4.
5. Place a ½” lock washer over the bolt threads and begin to thread a ½”-13 nut down
against the assembly.
Figure 4-4
6. Position the brass Power and Air Connector back into the bottom half of the boot.
Figure 4-5
7. Using your index finger to apply an upward force on the bolt, tighten the assembly
down.