Tweco 201 ts Thermal Arc User Manual

Page 18

Advertising
background image

THERMAL ARC 161 STL, 201 TS

INTRODUCTION

Introduction

2-4

Manual 0-5203

2.08 Specifications -201 TS

Power Source Part Number

W1003806

Mains Power

Nominal Supply Voltage

AC 115V

AC 208/230V

Number of Phases

Single Phase

Single Phase

Input Voltage Range

AC 104- 127V

AC 187- 253V

Nominal Supply Frequency

50/60 Hz

50/60 Hz

Effective Input Current (l1eff) for STICK (SMAW) Welding

18.3 Amps

15.8/14.2 Amps

Effective Input Current (l1eff) for LIFT TIG/HF TIG (GTAW)

Welding

16.4 Amps

12.3/11.1 Amps

Maximum Input Current (l1 max) for STICK (SMAW) Welding

∆ 27.2 Amps

∆ 35.2/31.6 Amps

Maximum Input Current (l1 max) for LIFT TIG/HF TIG (GTAW)

Welding

∆ 23.2 Amps

∆ 24.6/22.1 Amps

Single Phase Generator Requirements [Continuous rating

at nominal supply voltage with maximum output for STICK

(SMAW) welding]

4 KVA

7.3 KVA

Welding Output

Welding Current Range

Stick: 10 - 125 Amps

TIG: 10 - 160 Amps

Stick/TIG:

10 - 200 Amps

Nominal DC Open Circuit Voltage (OCV)

71V

71V

Welding Output, 104º F (40º C), 10 min.

(Quoted figures refer to STICK (SMAW) output)

100A @ 45%, 24.0V

87A @ 60%, 23.5V

68A @ 100%, 22.7V

200A @ 20%, 28V

116A @ 60%, 24.6V

90A @ 100%, 23.6V

Rated Input Current (A)

For STICK (SMAW) Welding

27.2A

Io = 100A @ 24.0V

35.2/31.6A

Io = 200A @ 28V

Rated Input Current (A)

For LIFT TIG (GTAW) Welding

23.2A

Io = 125A @ 15.0V

24.6/22.1A

Io = 200A @ 18V

Rated Output for STICK (SMAW) Welding

24.0V, 100A @ 45%

28V, 200A @ 20%

Rated Output for LIFT TIG/HF TIG (GTAW) Welding

15.0V, 125A @ 50%

18V, 200A @ 25%

Duty Cycle (%)

45% @ 100A

20% @ 200A

Welder Type

Inverter Power Source

Output Terminal Type

Heavy Duty Dinse

TM

50

Classification

Protection Class

IP21S

Standards

CSA E60974-1

EN50199

Cooling Method

Fan Cooled

Dimensions and Weight

Welding Power Source Mass

22 lb. (10 kg)

Welding Power Source Dimensions (Height x Width x Depth)

H 9.0” x W 5.3” x D 17.7”

(H230mm x W135mm x D450mm)

The recommended time delay fuse or circuit breaker size is 30 amp. An individual branch circuit capable of carrying 30 amperes

and protected by fuses or circuit breaker is recommended for this application. Fuse size is based on not more than 200 percent

of the rated input amperage of the welding power source (Based on Article 630, National Electrical Code)

Thermal Arc continuously strives to produce the best product possible and therefore reserves the right to change, improve or revise the speci-

fications or design of this or any product without prior notice. Such updates or changes do not entitle the buyer of equipment previously sold
or shipped to the corresponding changes, updates, improvements or replacement of such items.

The values specified in the table above are optimal values, your values may differ. Individual equipment may differ from the above specifications

due to in part, but not exclusively, to any one or more of the following; variations or changes in manufactured components, installation location

and conditions and local power grid supply conditions.

The Welding power source is of a drooping characteristic. The thermal protection switch is rated at 75° C.

Advertising
This manual is related to the following products: