INSTALLATION

THERMAL ARC 161 STL, 201 TS

Manual 0-5203

3-11 Installation

b) Low pressure gauges must be UL recognized

for the class of regulator they are being used on

according to UL252A.

!

WARNING

DO NOT use a regulator that delivers

pressure exceeding the pressure rating of the

downstream equipment unless pro visions

are made to prevent over-pressurization (i.e.

system relief valve). Make sure the pressure

rating of the down stream equipment is

compatible with the maximum delivery

pressure of the regulator.

5. Be sure that the regulator has the correct pressure

rating and gas service for the cylinder used.

6. Carefully inspect the regulator for damaged threads,

dirt, dust, grease, oil, or other flammable substances.

Remove dust and dirt with a clean cloth. Be sure the

inlet swivel filter is clean and in place. Attach the

regulator (Figure 3-6) to the cylinder valve. Tighten

securely with a wrench.

!

WARNING

DO NOT attach or use the regulator if oil,

grease, flamma ble substances or damage is

present! Have a qualified repair technician

clean the regulator or repair any damage.

Art # A-09845

Figure 3-6: Regulator to Cylinder Valve

7. Before opening the cylinder valve, turn the regulator

adjusting screw counterclockwise until there is no

pressure on the adjusting spring and the screw turns

freely.

8. Relief Valve (where provided): The relief valve is

designed to protect the low pressure side of the

regulator from high pres sures. Relief valves are not

intended to protect down stream equipment from high

pressures.

!

WARNING

DO NOT tamper with the relief valve or remove

it from the regulator.

!

WARNING

Stand to the side of the cylinder opposite the

regulator when opening the cylinder valve.

Keep the cylinder valve between you and the

regulator. For your safety, NEVER STAND IN

FRONT OF OR BEHIND A REGULATOR WHEN

OPENING THE CYLINDER VALVE!

9. Slowly and carefully open the cylinder valve (Figure

3-7) until the maximum pressure shows on the high

pressure gauge.

Art # A-09828

Figure 3-7: Open Cylinder Valve