15

3.03.02 Input Power

Each unit incorporates an INRUSH circuit and input voltage sensing circuit. When the MAIN INPUT
SWITCH is turned ON, the inrush circuit provides a pre-charging of the input capacitors. SCR’s in
the Power Control Assembly (PCA) will turn ON after the input capacitors have charged to full
operating voltage (after approximately 5 seconds).

Note 4

Note the available input power. Damage to the PCA could occur if 575VAC or higher is applied.


The following Primary Current recommendations are required to obtain the maximum welding current and
duty cycle from this welding equipment:

Current & Duty Cycle

Model

Primary Supply

Lead Size

(Factory Fitted)

Minimum Primary

Current Circuit Size

(Vin/Amps)

TIG STICK

208/31

-

230/28

-

8/4 AWG

460/14

300A @ 40%

-

minimum 208/45

-

230/41

-

3

Phase

460/21 -

300A @ 40%

8/3 AWG

208/51

-

minimum

230/46

250A @ 40%

-

208/76

-

ArcMaster

300 TS

1

Phase

230/68 -

250A @ 40%

Table 2 – 208-230/460V Primary Current Circuit sizes to achieve maximum current