Tweco 300 TS Arcmaster(Feb2006) User Manual
Page 23
17
3.04 Specifications
Parameter
Rated Output
Amperes
Volts
Duty Cycle
300 TS
208-230/460VAC
300
32
40%
Duty Cycle
300A / 32V @ 40% (3ph)
200A / 28V @ 60% (3ph)
250A / 30V @ 40% (1ph)
Output Current Range
5 – 300 Amps
Open Circuit Voltage
65V
Dimensions
Width
Height
Length
8.3” (210mm)
16.5” (420mm)
17.7” (450mm)
Weight
52.9 lb. 24 kg
Output @ Rated Load
Rated Input Voltage
Output Amperes
Output Volts
Duty Cycle
KVA
KW
Three-phase
208-230/460V
300A
32V
40%
18.0
12.0
Single-phase
208-230V
250A
30V
40%
15.7
9.4
Output @ No Load
KVA
KW
0.5
0.13
Input Volts Three Phase
208V
230V
460V
Input Volts Single Phase
208V
230V
Amperage Draw @
Rated Load
45
41
21
97
87
No Load
1.4
1.3
0.7
2.5
2.2
Thermal Arc continuously strives to produce the best product possible and therefore reserves the
right to change, improve or revise the specifications or design of this or any product without prior
notice. Such updates or changes do not entitle the buyer of equipment previously sold or
shipped to the corresponding changes, updates, improvements or replacement of such items
.