17

3.04 Specifications

Parameter
Rated Output
Amperes
Volts
Duty Cycle

300 TS

208-230/460VAC
300
32
40%

Duty Cycle

300A / 32V @ 40% (3ph)
200A / 28V @ 60% (3ph)
250A / 30V @ 40% (1ph)

Output Current Range

5 – 300 Amps

Open Circuit Voltage

65V

Dimensions
Width
Height
Length


8.3” (210mm)
16.5” (420mm)
17.7” (450mm)

Weight

52.9 lb. 24 kg

Output @ Rated Load
Rated Input Voltage
Output Amperes
Output Volts
Duty Cycle
KVA
KW

Three-phase

208-230/460V
300A
32V
40%
18.0
12.0

Single-phase

208-230V
250A
30V
40%
15.7
9.4

Output @ No Load
KVA
KW


0.5
0.13

Input Volts Three Phase

208V
230V
460V

Input Volts Single Phase

208V
230V

Amperage Draw @

Rated Load

45
41
21

97
87

No Load

1.4
1.3
0.7

2.5
2.2

Thermal Arc continuously strives to produce the best product possible and therefore reserves the
right to change, improve or revise the specifications or design of this or any product without prior
notice. Such updates or changes do not entitle the buyer of equipment previously sold or
shipped to the corresponding changes, updates, improvements or replacement of such items

.