7.04 Guide for Selecting Filler Wire Diameter

Filler Wire Diameter

DC Current Range

(Amps)

1/16” (1.6 mm)

20 - 90

3/32” (2.4 mm)

65 - 115

1/8” (3.2 mm)

100 - 165

3/16” (4.8 mm)

200-350


Table 9 – Filler Wire Selection Guide

NOTE 7

The filler wire diameter specified in Table 9 is a guide only. Other diameter wires may
be used according to the welding application.

7.05 Shielding Gas Selection

Alloy

Shielding Gas

Aluminium

&

alloys

Argon

Carbon

Steel

Argon

Stainless

Steel

Argon

Nickel

Alloy

Argon

Copper

Argon

Titanium

Argon


Table 10 – Shielding Gas Selection

7.06 TIG Welding Parameters for Low Carbon & Low Alloy Steel Pipe

Electrode Type &

Diameter

Current Range DC

Amperes

Filler Rod for

Root Pass

Joint Preparation

Thoriated 2%

3/32” (2.4 mm)

120 - 170

Yes

Thoriated 2%

3/32” (2.4 mm)

100 - 160

Yes

Thoriated 2%

3/32” (2.4 mm)

90 - 130

No


Table 11 – TIG Welding Parameters for Low Carbon & Low Alloy Steel Pipe

Advertising