Tweco 300 TS Arcmaster(Feb2006) User Manual

Page 27

Advertising
background image

21

8

SMART Logic Switch

Manual slide switch mounted on the back panel selects for proper input voltage. If this slide
is not set to the position that matches the input voltage from the electrical source the Smart
Logic circuit will inhibit welding power source output. The digital meter will show primary
input error code.

9

Gas Inlet

The Gas Inlet is a 5/8 – UNF female gas fitting.

4.02 Weld Process Selection for ArcMaster 300 TS

Weld

Mode

Weld Process

Selection

STICK

HF

TIG

LIFT

TIG

Description

STD

Yes Yes

Yes

2T operation in TIG Modes using remote devices to
control contactor & current.

SLOPE

No Yes

Yes

4T operation in TIG Modes with crater fill using a
remote contactor device to control sequence.

REPEAT

No Yes

Yes

4T operation in TIG Modes with repeat operation
and crater fill using a remote contactor device.

SPOT

No Yes

No

2T operation spot welding in HF TIG using a
remote contactor device.

PULSE ON/OFF

No

Yes

Yes

Pulse operation in TIG Modes.

Contactor ON/OFF

Yes

No

Yes

Contactor operation in Stick and Lift TIG Mode.

Operation

PANEL/REMOTE

Yes

Yes

Yes

Selects in Operation Panel Board or Remote.


Table 3 – Weld Process Selection verses Weld Mode for ArcMaster 300 TS

Advertising