05 smaw (stick) welding & carbon arc gouging, Operation excel arc 6045 – Tweco 6045 Excel Arc User Manual

Page 31

Advertising
background image

OPERATION EXCEL

ARC

6045

August 26, 2011

4-5

Manual 0-5213

SW2 SW3

SW1

R295

R275

R295

HOT START DURATION- Continuously adjustable from 0.5 to 2 seconds.

R275

HOT START VALUE - Continuously adjustable between 0 - 100% of the LOCAL

or REMOTE demand level up to 700 amps total.

Art# A-10895

Figure 4-4: Hot Start Level and Duration Adjustments

4.05 SMAW (Stick) Welding & Carbon

Arc Gouging

1. Connect the work cable and electrode holder lead. The

positive lead should be connected to the POSITIVE
OUTPUT RECEPTACLE.

2. Connect the work clamp to the work piece or work

table.

3. Turn ON/OFF SWITCH (SW1) to ON position.

NOTE

The output enable LED (green) will be ON at
this time.

4. Set MODE SELECTOR SWITCH (SW2) to STICK

position (SMAW / CAG - CC).

5. If HOT START feature is desired, turn HOT START

SELECTOR SWITCH (SW3) to ON position.

5a. If required, to adjust HOT START current level and

duration.

6. Set ARC FORCE CONTROL POTENTIOMETER (R2) to

the maximum level.

7. Set LOCAL / REMOTE SWITCH (SW4) to LOCAL.

8. Set VOLTAGE CURRENT CONTROL POTENTIOMETER

(R1) to select desired current level.

9. If VRD protection is desired, set SW1-A located on the

Main PCB to ON (DN) position. Factory setting is ON
(Down) position.

10. Hold electrode clear of work.

11. Strike the arc.

12. When welding / gouging is fi nished, turn the ON/OFF

SWITCH (SW1) to OFF position.