08 troubleshooting stick (smaw /cag) mode problems, 09 troubleshooting tig (gtaw) modeproblems, 10 troubleshooting mig (gmaw /fcaw) mode problems – Tweco 6045 Excel Arc User Manual

Page 37: Service excel arc 6045, 09 troubleshooting tig (gtaw) mode problems, 10 troubleshooting mig (gmaw / fcaw) mode problems

Advertising
background image

SERVICE EXCEL

ARC

6045

August 26, 2011

5-5

Manual 0-5213

For LOCAL VOLTAGE or CURRENT control:

2. LOCAL / REMOTE SWITCH (SW4) is set in REMOTE

position.

a. Switch SW4 to LOCAL position.

For REMOTE VOLTAGE or CURRENT control:

2. Remote potentiometer or cable is open.

a. Check continuity.

D. Welding Arc will not transfer.

1. Defective Positive or Negative output cables.

a. Check continuity.

2. Work cable not connected or poor connection to work.

a. Check / clean connections.

E. Poor weld performance.

1. Incorrect polarity.

a. Verify welding cable polarity is correct for the

welding mode and application requires.

5.08 Troubleshooting STICK (SMAW /

CAG) Mode Problems

A. ON / OFF INDICATOR is ON. No arc can be

established. OUTPUT on INDICATOR is OFF.

1. Defective control board.

a. Replace control board.

2. Defective remote OUTPUT ENABLE (START) switch or

cable.

a. Check continuity.

B. OUTPUT ON INDICATOR is ON but there is no

output voltage from the unit.

1. Take unit to Authorized Service Facility.

C. Hard or intermittent starting of the arc.

1. Insuffi cient output current.

a. Increase OUTPUT VOLTAGE /CURRENT

POTENTIOMETER (R1) to higher setting.

2. HOT START SWITCH (SW3) is in OFF position.

a. Switch SW3 to ON position.

3. Insuffi cient HOT START amperage or duration.

a. Adjust HOT START current level and/or duration

trimpots.

4. Electrodes sticking to work piece. ARC FORCE

CONTROL POTENTIOMETER (R2) is set too low.

a. Increase R2 setting.

5.09 Troubleshooting TIG (GTAW) Mode

Problems

A. ON /OFF INDICATOR is ON. OUTPUT ON

INDICATOR is OFF. No output.

USING REMOTE CONTROL SWITCH FOR OUTPUT
ENABLE CONTROL:

1. Defective remote OUTPUT ON (CONTACTOR ON)

switch.

a. Check switch continuity.

2. Remote control cable is open.

a. Check for continuity between J1 plug pins A &

B with remote switch closed.

B. OUTPUT ON INDICATOR is ON but there is no

output voltage from the unit.

1. Take unit to an Authorized Service Facility.

5.10 Troubleshooting MIG (GMAW /

FCAW) Mode Problems

A. ON /OFF INDICATOR is ON. OUTPUT ON

INDICATOR is OFF. No output.

1. No remote OUTPUT ENABLE (CONTACTOR ON) signal.

a. Verify Start signal to J1 plug from feeder. (1 of

four possible signals.)

i) Contact closure between pins A & B.

ii) Contact Closure between pins R & S.

iii) Contact closure between pins D & E.

iv) Contact closure between pins P & R.

2. Circuit Breaker

Tripped.

a. Check/Reset CB3,CB4,CB5.

B. OUTPUT ON INDICATOR is ON but there is no

output voltage from the unit.

1. Take unit to an Authorized Service Facility.