11. Battery Charge Lamp – When the ON/OFF Switch is

turned on the Battery Charge Lamp will Glow. For
normal operation when the engine is running the
Battery Carge Lamp will be off. Should the Charging
circuit or Battery fail the Battery Warning Lamp will
Turn-on and the engine will shut off.

12. Remote AMPERAGE / VOLTAGE Switch – Allows

remote amperage/voltage device operation through
the 14 pin receptacle.

13. Process Selector switch : CC/CV – Allows the

operator to select the CC (Constant Current) process
or CV (Constant voltage) process.

14. Remote Contactor switch – Allows for the output

contactor to be controlled through the 14 pin
receptacle. When in the Panel position welding
output is present at the output terminal when the
engine is running. When in Remote position output is
controlled through a 14 pin remote device.

15. Arc Control – The Arc Control is use in the SMAW

mode only. Rotate the control clockwise to increase
the short circuit current available to control the
welding arc.

16. 14 Pin receptacle - Used for remote Contactor,

amperage control, and wire feeder control.

17. Serial number.
18. Welding Receptacle: Electrode-Positive output

welding connection for CC (Constant Current) and
CV (Constant Voltage).

19. Choke – Pull knob out engges Choke. Push knob in

for normal operation.

20. 24V AC 10A Circuit breaker – Push to reset.

Controls 24V power source for wire feeders.
Controlled through the 14 pin receptacle.

21. Hour meter - Monitors Time in hours when the

engine is on.

22. Fuel Gauge – Monitors fuel level
23. START button – Used to start the engine. Set the

ON/OFF switch to ON, push START button to the
start the engine. When engine starts release button

24. Engine ON/OFF switch - Place in the ON position to

operate generator. Use the START button to start the
engine. To shut off engine place switch in stop
position.

25. Engine Min/Max R.P.M. switch

26. 13A Circuit breaker - 3 poles circuit breaker controls

460V three phase power source.

27. 460V Output - Access for three phase 460V 60 Hz

connections. Connect Line1, 2 and 3 to the output
side of the circuit breaker and the ground to the bolt
mounted beside the circuit breaker.

2.05 Dimensions and Weight

Height

710mm

27.9”

Width

530mm

20.86”

Length

1080mm

42.52”

A

15mm

.59”

B

1050mm

41.34”

C

34.5mm

1.36”

D

424mm

16.69”

E

10.5mm Dia.

.41” Dia.

Weight

248 Kg

546.5 lb

2.06 Maximum Welding

Generator Operating Angles

Do not exceed operating angles while running or engine
damage will occur.

The operating angle is a maximum of 25 degrees.

GENERAL INFORMATION