WARNING: ENGINE FUEL CAN CAUSE FIRE OR
EXPLOSION.

• Stop engine before fueling.

• Do not fuel while smoking or near sparks or flames.

• Do not overfill tank-clean up any spilled fuel.

REMOVE FUEL CAP SLOWLY-FUEL SPRAY
MAY CAUSE INJURY. FUEL MY BE UNDER
PRESSURE. Rotate fuel cap slowly and wait until
hissing stops before removing cap. Engine must be
cold and on a level surface.

2.10 Generator Auxiliary

Power System

Standard Receptacles

(1) Circuit breakers to protect (2) GFCI receptacles from
overload.

(2) 120 V 15 A AC Duplex GFCI receptacle. Supplies 60
Hz single-phase power at maximum speed (3600 rpm).
Maximum output each receptacle is 1.8 kVA/kW.

(3) Circuit breakers to protect (4) 240 V receptacle from
overload.

(4) 240 V 50 A AC receptacle. Supplies 60 Hz single-
phase power at maximum speed (3600 rpm). Maximum
output is 8.5 kVA/kW.

(5) Earth ground connection.

460 Three Phase connection
(1) 460 V 13 A AC three phase Circuit Breaker
connection. Supplies 60 Hz three-phase power at
maximum speed (3600 rpm). Maximum output is 10
kVA/kW.

To connect load remove the two retaining knobs holding
the access panel. After opening the panel connect a cable
to be used to supply the 460V three phase load to the
three phase circuit breaker mounted to the access panel.
Connected the ground cable to the bolt mounted next to
the circuit breaker. Route the cable through the cable
clamp (2) and secure cable. Re-secure the access panel
with the two retaining knobs to the front panel.

5

TECHNICAL SPECIFICATIONS