5.07 14 pin Receptacle Signals

Socket Pin

Function

A

24VAC auxiliary high side.

B

Input to energize solid state contator (Contact closure between pin A and pin B)

C

5k ohm (maximum) connection to 5k ohm remote control potentiometer

D

Zero ohm (minimum) connection to 5k ohm remote control potentiometer

E

Wiper arm connection to 5k ohm remote control potentiometer

F

Not Used

G

24/115 VAC circuit common, also connected to chassis

H

Not Used

I

115 VAC auxiliary high side

J

115 VAC input to energize solid state contactor (Contact closure between pin I and pin J)

K

Chassis ground