5.07 14 pin Receptacle Signals
Socket Pin
Function
A
24VAC auxiliary high side.
B
Input to energize solid state contator (Contact closure between pin A and pin B)
C
5k ohm (maximum) connection to 5k ohm remote control potentiometer
D
Zero ohm (minimum) connection to 5k ohm remote control potentiometer
E
Wiper arm connection to 5k ohm remote control potentiometer
F
Not Used
G
24/115 VAC circuit common, also connected to chassis
H
Not Used
I
115 VAC auxiliary high side
J
115 VAC input to energize solid state contactor (Contact closure between pin I and pin J)
K
Chassis ground