Section 5: customer/operator service, 01 introduction, 02 general maintenance – Tweco FP-55 User Manual

Page 27

Advertising
background image

Manual 0-2846

5-1

SERVICE

SECTION 5:

SERVICE

5.01 Introduction

This section describes basic maintenance procedures per-
formable by operating personnel. No other adjustments
or repairs are to be attempted other than by properly trained
personnel.

NOTE

Trained personnel can receive more advanced
troubleshooting instructions and information on
parts replacement by requesting Service Manual
0-2847.

5.02 General Maintenance

A. Maintenance Schedule

WARNING

Disconnect primary power to the system before dis-
assembling the torch, leads, or power supply.

To clean the unit, open the enclosure per procedures in
section 5.05-A, Cover Removal, and use a vacuum cleaner
to remove any accumulated dirt and dust. The unit should
also be wiped clean. If necessary, solvents for cleaning
electrical apparatus may be used.

Perform routine maintenance according to the schedule in
Appendix 3. The actual frequency of maintenance may
need to be adjusted according to the operating environ-
ment.

B. Filter Regulator Element Replacement

The Filter /Regulator Assembly is located on the rear panel.
For better system performance, the Filter/Regulator As-
sembly filter element should be checked per Appendix 3,
Maintenance Schedule, and either cleaned or replaced.

1.

Remove power from the power supply; turn off the
gas supply.

Filter
Element

Regulator
Assembly

Spool

Spring

Baffle
Ring

A-02954

Bowl

Figure 5-1a Filter/Regulator - Removing the Filter

Element (units with type A Regulator/Filter)

A-02995

Regulator/Filter

Assembly

Spool

Bowl

Spring

Filter
Element

Baffle
Ring

Figure 5-1b Filter/Regulator - Removing the Filter

Element (units with type B Regulator/Filter)

Advertising