07 volt - amp curves, Volt - amp curves -3, Introduction firepower fp-95 – Tweco FP-95 Mini MIG User Manual

Page 19

Advertising
background image

INTRODUCTION

FIREpOwER Fp-95

Introduction

2-3

Manual 0-5122

The recommended time delay fuse or circuit breaker size is 20 amp. An individual branch circuit capable of carrying 30 amperes

and protected by fuses or circuit breaker is recommended for this application. Fuse size is based on not more than 200 percent

of the rated input amperage of the welding power source (Based on Article 630, National Electrical Code)

Thermal Arc continuously strives to produce the best product possible and therefore reserves the right to change, improve or

revise the specifications or design of this or any product without prior notice. Such updates or changes do not entitle the buyer

of equipment previously sold or shipped to the corresponding changes, updates, improvements or replacement of such items.

The values specified in the table above are optimal values, your values may differ. Individual equipment may differ from the above

specifications due to in part, but not exclusively, to any one or more of the following; variations or changes in manufactured

components, installation location and conditions and local power grid supply conditions.

2.07 Volt - Amp Curves

FP-95 FIREPOWER Vin=115V 60Hz

0

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

OUTPUT CURRENT

OU

TP

UT

V

OL

TA

GE

Art # A-09068

Figure 2-1: Volt/Amp curves of the FirePower 95

Advertising