Tweco 7-3439 User Manual

General information, Parts supplied, Installation

Advertising
background image

© 1998 Thermal Dynamics Corp., Printed in USA

Installation Instructions 5/21/99

Manual 0-2758

RPT Adapter Kit

Catalog # 7-3439

Installation Instructions

General Information

This Replacement Torch Adapter Kit is to be used to connect the Thermal Dynamics Plasma RPT Series Cutting Torch to the
following equipment:

HARRIS System 50, 65 and 100

Parts Supplied

The following parts are included in this kit:

• Control Connector Wires with Connectors (1 ea)
• Tie-Wrap (1 ea)

Installation

Install the Adapter Kit per the following procedure:

1. Turn OFF the power supply.

2. Disconnect the main input power to the power supply.

3. Remove the existing torch from the power supply, removing

covers as required.

4. Connect the pilot wire (+) from the replacement torch to the

Power Supply and tighten securely

5. Connect the Negative/Plasma Lead from the replacement torch

to the Power Supply. Slide the protective boot over the lead
connection.

6. Connect the Control Connector Wires (see NOTE), with two

connectors, to the two mating connectors on the replacement
torch leads.

7. Connect the fastons of the Control Connector Wires to the

Power Supply.

8. Cover the connections with the original rubber boot and secure

with the supplied tie-wrap.

9. Reinstall any covers removed (see WARNING).

10. Install the proper torch consumables for the Power Supply amperage.

11. Reconnect main input power to the Power Supply and turn the unit ON.

12. Set air pressure to 60 - 70 psi (4.1 - 4.8 bar).

13. Test torch for proper operation.

NOTE

For Mechanized Systems refer to the
Torch Control Cable Wiring Diagram
on the last page of this Manual.

WARNING

Make sure that the Control Connector Wires DO
NOT contact the Negative/Plasma Lead after all
leads are connected.

Torch Control

Connectors

Pilot Lead

Torch Lead Assembly

Negative/Plasma Lead

A-02483

Control Connector

Wires with Connectors

To

Po

wer Supply

(-) Fitting

To

Po

wer Supply

Control Connector

To

Po

wer Supply

Pilot Connector

Fastons

Advertising