General Information

This Replacement Torch Adapter Kit is to be used to connect the Thermal Dynamics Plasma RPT Series Cutting Torch to the
following equipment:

Thermal Dynamics PAK 3XR, 5XR, 5XT, 6XR, 7XR, 625XR and 750XR

Parts Supplied

The following parts are included in this kit:

• Control Connector Plug with Connectors (1 ea)
• Secondary Gas Output Plug (1 ea)
• Adapter Fitting (Flow) With Orifice (1 ea)

Installation

Install the Adapter Kit per the following procedure:

1. Turn OFF the power supply.

2. Disconnect the main input power to the power supply.

3. Remove the existing torch from the power supply,

removing covers as required.

4. Place the Adapter Fitting (Flow) provided into the Power

Supply torch power cable fitting (-) and tighten securely.

5. Connect the pilot wire (+) from the replacement torch to

the Power Supply and tighten securely.

6. Connect the Negative/Plasma Lead from the replacement

torch to the Power Supply. Slide the protective boot
over the lead connection.

7. Connect the Control Connector Plug (see NOTE), with

two connectors, to the two mating connectors on the
replacement torch leads.

8. Connect the Control Connector Plug to the Power

Supply.

9. For dual gas machines, install the supplied left-handed Secondary Gas Output Plug to block off the secondary gas output.

10. Adjust the HF Spark Gap setting inside the Power Supply use the following procedure:

a.

Remove the Right Side Panel from the Power Supply.

b.

Locate the Spark Gap Assembly on the Upper Equipment Panel.

c.

Using an allen wrench loosen the set screw on the top of the outside brass block until the electrode can be moved.

d.

Adjust the electrode for the proper 0.030" (0.76 mm) gap between the two electrodes.

e.

Tighten the set screw to secure the electrode.

f.

Re-install the Power Supply Side Panel.

NOTE

For Mechanized Systems refer to the
Torch Control Cable Wiring Diagrams
in the Manual supplied with the RPT
Torch.