Tweco 9-9418 User Manual

General information, Procedure

Advertising
background image

Manual 0-4737

1

General Information

These instructions cover the CCM (Command & Control

Module) for Thermal Dynamics Automated Plasma Cut-

ting Power Supplies. Do not install this module on any

other equipment.

There are two types of module. One includes an external

strain relief cover assembly protruding from the back

panel. The other has a flat back panel. Refer to the illustra-

tion to confirm that the module is correct for the power

supply being serviced.

External

Connection

Cover

CCM Type 1

CCM Type 2
(Cat. No. 9-9418)

Art # A-06871_AB

CCM Type 3
(Cat. No. 9-9417)

USB

NO LONGER AVAILABLE

Command & Control Module,

No. 9-9417 / 9-9418

for Automated Plasma Cutting

Power Supplies

Installation Instructions

Procedure

WARNING

Disconnect primary power at the source and

bleed down the system before installing, in-

specting, or repairing this equipment.
Only a qualified technician should install or

service this equipment.

1. Remove the power supply right side panel. Set the

panel aside carefully. A ground wire connects to the

inside of the side panel. Disconnect this wire if neces-

sary to provide more room to work.

Art # A-07333

CAUTION

There is one section in these instructions for

each type of module. Be sure to follow the

correct section for the type of module being

replaced.

Original Publication Date: 2006

Manual no.: 0-4737

Revision Date: 2014

Revision: AD