Removal and Replacement, Type 1 Module

A. Disconnect External Connections (Type 1 Module)

Art # A-06873

Power Supply

Right Side Panel

To Gas Control Module

To Remote HMI

(if installed)

To Slave Power Supply

(if installed)

1

2

Power

Supply

Rear P

anel

Connection Cover

Connection Cover

Side Panel

Cable Loops

1. Remove the side panel from the connection cover.

2. Carefully label and disconnect all external cables connected to the module.

3. Remove and keep the strain relief nut(s) holding the strain relief(s) to the connection cover. Carefully pull the

cable(s) and strain relief(s) out of the connection cover. Leave the strain relief(s) on the cable(s).

B. Disconnect Internal Wire Harnesses

1. A wire harness connects the module rear panel to the larger PC Board in the module. Leave this harness in

place. Carefully label and disconnect all other internal wire harnesses connected to the module. Take care to

label the harnesses connected to terminals J1 and J7 properly to ensure connections to the correct terminals

on the replacement assembly. The harness connectors include latches that must be compressed to release

them from the PC Board receptacles.

2. Loosen, but do not remove, the internal bolt fastening the module to the power supply inner horizontal panel.

3. Remove the hardware holding the module rear panel to the power supply rear panel. Save the hardware for

re-use.

4. Carefully slide the module out of the power supply. Keep the module nearby to serve as a reference for setting

the switches on the replacement module.