Tweco 9-9418 User Manual

Page 5

Advertising
background image

Manual 0-4737

5

SW6: OK-to-Move: Contact closure, 120VAC @ 1A (Factory default setting) or
DC Volts (16-18vdc@ up to 100 ma.)
SW11: Analog Current Control. B = from Gas Control (Factory default setting) or A = from CNC.
Position A requires that SW-8-2 be ON.

SW12-1/2/3/4: Divided Arc signal

All = OFF = 50:1 (Factory default setting)

1 = ON = 16.6:1
2 = ON = 30:1
3 = ON = 40:1
4 = Not used.

Art # A-07673

Only 1 on at a time.

SW11

SW13

SW6

SW12

SW13: TVA and XTL Switch positions

SW13

1

2

1

2

TVA

XTL TVA

NOTE

Standoff Control SC-11 requires Switch 12-1 set to ON.

Reinstall the power supply side panel. Reconnect input power. Test the system for proper operation.