Front panel controls and indicators – VICI 230 Dynacalibrator User Manual

Page 40

Advertising
background image

36

MAIN POWER switch, indicator, and circuit breaker
The rocker switch provides primary power to all circuits. The LED indicator lights when main power is on.
A 6 amp circuit breaker is installed in the main primary power input line to all circuits.

HEATER POWER switch, indicator, and circuit breaker
The rocker switch provides primary power to the heater circuits when the main power switch is on.
The LED indicator lights when heater power is on. A 4 amp circuit breaker is installed in the primary
power line to the permeation chamber heater circuits.

PERMEATION CHAMBER
This is the chamber which holds the permeation devices. A tool is provided to rotate the panel lock screw
90° counterclockwise to unlock the cap.

PERMEATION CHAMBER FLOW INDICATOR PANEL
Permeation chamber flow rates are read directly from this display. Carrier flow rates are factory set at 100
SCCM (typically), and should not be altered by the end user. Please contact VICI if a different carrier flow
rate is required.

TEMPERATURE READOUT AND CONTROLLER
The front panel displays the current chamber temperature and the control status of the instrument,
indicated by the PNL and TMP lights. The chamber temperature can be set manually through the controls
on the front panel or remotely through RS-232 communication. (Refer to the chapter entitled “Serial Port
Communications on page 16)
. After a temperature set point is entered by either method, it is written to
memory so that after a power failure the unit will return to the condition previously established.

DILUTION FLOW CONTROL VALVE
Turn the knob to adjust the flow rate of the dilution stream prior to mixing with carrier and trace gas.

DILUTION FLOW INDICATOR PANEL
This indicator will show the dilution flow rate in SLPM as well as providing temperature and inlet pressure
indications.

OVEN TEMPERATURE UPPER LIMIT
A thermostat provides a safety shutoff at this user-defined setpoint, usually 5 - 10 degrees above the normal
run temperature of the permeation device in use. If the oven runs out of control and the temperature goes
above this setting, power to the oven heater is shut down and a “PFAIL” indication appears in the temperature
display window.

DILUTION FLOW

INDICATOR PANEL

DILUTION

FLOW CONTROL

VALVE

MODE

SELECTOR

MODE

INDICATORS

HEATER

CIRCUIT

BREAKER

MAIN

CIRCUIT

BREAKER

HEATER

POWER

SWITCH

HEATER

INDICATOR

MAIN

POWER

INDICATOR

MAIN

POWER

SWITCH

PERMEATION

CHAMBER

CHAMBER FLOW

INDICATOR PANEL

TEMPERATURE

EQUILIBRIUM

INDICATOR

TEMPERATURE

DISPLAY

OVEN TEMPERATURE

UPPER LIMIT

Metronics Inc.

SHUTDOWN

30°

120°

MODE CONTROL

REMOTE

SPAN

ZERO

DYNACALIBRATOR

MODEL 230

PERMEATION CHAMBER

LOCK

TEMPERATURE °C

PNL TMP

SET

4A

6A

MAIN

HEATER

DILUTION

FLOW

CONTROL

MODE

Volume

Mass

Main

14.69

20.5

0.00

0.000

0.000

Air

PSIA

C

Set Pt.

1.234

SCCM

MODE

Volume

Mass

Main

14.69

20.5

0.00

0.000

0.000

Air

PSIA

C

Set Pt.

1.234

SCCM

Figure 12: Front panel controls and indicators, Electronic Flow Control option

Appendix: Electronic Flow Control Option

Front Panel Controls and Indicators

Advertising