(5) As soon as the 8 minutes PEC recording has elapsed, PEC Play: xxx (numbers) will come
out on the screen. From this stage the recorded PEC compensation value will be
reproduced. Continuing corrections with the RA+, RA – keys will improve the corrections
and will make your tracking accuracy increase further.



Stop the PEC recording

(1) Press Menu to display the System Menu. Move the cursor to PEC with the

keys

and press Select to enter.


(2) Choose Play Stop (or Rec. Stop) in the PEC screen and press the Select key to return to

the System Menu.

*If the PEC recording is done over one cycle, Play Stop will be shown on the screen. If the
PEC recording is less than one cycle, Rec. Stop will be indicated.

The PEC recording can be stopped any time after the 8 minutes has elapsed if you are
satisfied with the recorded tracking accuracy. As the PEC recording completes in 8
minutes as one cycle, it is best to have the PEC recording stopped at the end of the cycles.

Restart the PEC recording
As you stop the PEC recording, the screen changes to the System Menu. Move the cursor
to PEC with the

keys and press Select to enter. Choose Rec. Start in the PEC screen

and press Select to start the PEC recording again.


*If the PEC recording is done over one cycle, Play Start will be shown underneath the
indication of

Rec. Start. If the PEC recording is less than one cycle, Play Start won’t be indicated.