Weller WRK User Manual

Page 4

Advertising
background image

4-9

WRK

Note Also read and observe the Operating Instructions of your control

unit.

1. Carefully unpack the WRK.

2. Assemble reflow nozzles (2, 3), tripod (4) and pick-up tool (6) in

holder (1).

3. Switch off the control unit.

4. Connect the hot-air pencil (HAP) with air hose to the "Air“ outlet of

the control unit and insert with the attachment plug in the correct

connection socket of the repair station. Lock by turning clockwise

slightly (connect HAP 1 with adapter only).

5. Connect vacuum pick-up (6) with vacuum hose to the vacuum

pick-up ports of the control unit.

6. Attach a suitable reflow nozzle or tripod to the vacuum pick-up

(see Sections 5.1 and 5.2).

It is possible to use large reflow nozzles, small reflow nozzles with

tripod or the tripod on its own to lift off small components with the

vacuum pick-up tool.

4.1 Mounting the Reflow Nozzle

1. Check the .400 ", (10 mm) diameter vacuum pick-up tool to ensure

the components (clamping sleeve (5), marker ring (7) and vacuum

cup with heat shield (10)) are correctly installed.

2. Assemble nozzles directly to vacuum pick-up tool (6) using the

clamping sleeve (5).

Note The reflow nozzles are not assembled directly to the .180 ", (4.5

mm) vacuum pick-up tool. Ensure the tripod and the.180 ", (4.5 mm)

diameter vacuum pick-up tool are correctly positioned in the nozzle

and on the component.

4.2 Mounting the tripod

1. Check the .180 ", (4.5 mm) diameter vacuum pick-up tool to

ensure the components (clamping sleeve (5), marker ring (7) and

vacuum cup with heat shield (10)) are correctly assembled.

2. Screw tripod (4) to the vacuum pick-up tool (6) using the clamping

sleeve (5).

You can use the .180 ", (4.5 mm) diameter vacuum pick-up tool

mounted in this way with a Large reflow nozzle (A1) or with Small a

reflow nozzle (B1). When working without a reflow nozzle, you can

also use a .400 " (10 mm) diameter vacuum pick-up tool.

Advertising