Weller WA2000 User Manual

Page 2

Advertising
background image

2005 Cooper Industries, Inc.

1

S805

3/05

INTRODUCTION

The WA2000 soldering iron analyzer was developed for testing soldering irons for
compliance with the DOD-STD-2000 and the new MIL-STD-2000 specifications. This
portable unit is capable of testing tip temperature, tip to ground resistance and tip to
ground noise (mVRMS). Correctly used and maintained, it is the most accurate of any
comparable tester currently available on the market. Please read this document
thoroughly, prior to using the WA2000.

TEMPERATURE


Range:

32 to 10400°F (0 – 560°C)

*Accuracy: Contact

Pyrometer,

±.1% over a ten degree span (stability).

Auxiliary

T/C,

±.5% of reading (Absolute) ±1 digit.

Resolution: 1°F or 1°C, user selectable
Sensor:

CP-01** or CP-02** Contact Pyrometer, K-111, K-121, K-181 Type K
Thermocouple assembly.


*NOTE:

Analyzer accuracy only. Tolerance of thermocouple and external fixturing
must be added.


**Patent pending

TIP OHMS TO GROUND


Range:

0 to 100 Ohms

Accuracy:

1% of reading ±.2 Ohms

Resolution: .1

Ohms

Test Current: 10 milliamperes AC Current Source to RMS Conversion.
US

Patent

#5,073,758

TIP VOLTAGE TO GROUND


Range:

0 to 100 mV RMS, Crest Factor of 3

Accuracy:

1% of Reading ±0.2mV

Resolution: 0.1

mV

Measurement: True RMS conversion

Digital Display: 3 1/2 Digit LCD

Power: 9VDC

Battery

Battery Life: 50hrs.

Advertising