SPECIFICATIONS

1. Power Input: 120VAC ±10%, 60Hz, (240VAC ± 10%, 50/60 Hz), 60 watts
2. Power unit output voltage: isolated 24VAC @ 2.1 amperes.
3. Size: 4.5" x 5.9" x 3.6"
4. Line Cord: 3 wire, UL recognized.
5. Tip temperature control range: 350°F to 850°F (175°C to 455°C).
6. Control setting resolution: 10°F (5°C).
7. Stability: ±10°F (±6°C) per MIL-STD-2000.
8. Absolute accuracy: Average tip temperature is calibrated to ±9°F (±5°C) at idle with no load.
9. Ambient temperature range: 60°F to 110°F (16°C to 44°C).
10. Housing made with Electrostatic Protective Material as required in MIL-B-81705.
11. Housing passes Static Decay test per Federal Test Method Standard No. 101, method 4046.
12. Weller

®

ESD tools comply with DOD-HDBK-263.

13. WTL1000S units are UL listed and meet DOD-STD-2000, MIL-STD-2000, MIL-S-45743, W-S-6536,

W-S-570, DOD-STD-1686.

TROUBLESHOOTING GUIDE

WARNING:

AC line voltage is present inside power unit even when power

switch is off. Refer service to qualified personnel.

NOTE:

Access to internal parts may be gained by removing four rubber feet,

four screws under feet and top case.
TOOL DOES NOT HEAT
With line cord unplugged and power switch on, check for approximately 21 ohms at line cord blades for

120VAC units (55 ohms for 240VAC units).

• Check fuse, located on bottom of case - replace if required. Use slow blow fuse - 0.6A for 120VAC

(0.3A for 240VAC).

• Check power switch - replace if defective.

• Check line cord - repair or replace if defective.

• Check transformer primary - replace transformer if defective.

With line cord plugged in and power switch on, check for 24VAC ±10% between pins #1 and #4 of tool

receptacle.

• Check transformer secondary for 24VAC ±10% - replace transformer if defective.

• Check wiring to printed circuit board assembly - repair or replace if defective.

• Replace printed circuit board assembly.

With line cord plugged in and power switch on, check for 5 VDC ±1 VDC, between pins #3 and #4 of tool

receptacle

.

• Replace printed circuit board assembly.

Check wiring from tool receptacle to printed circuit board.

• Repair or replace if defective.

Replace soldering tool with known good tool and recheck.

• Troubleshoot soldering tool using guide in soldering iron tech sheet.