10 Error messages and error clearance

Message/symptom

Possible cause

Remedial measures

Display: "- - -

−

Tool has not been detected

−

Tool defective

−

Desoldering iron and hot air

tool are connected

simultaneously

−

Check connection of tool to

device

−

Check connected tool

−

Disconnect one of the tools

No air at HAP

−

Air hose not or incorrectly

connected

−

Connect air hose to AIR nipple

No vacuum at desoldering tool − Vacuum hose not or

incorrectly connected

−

Desoldering nozzle clogged

−

Connect vacuum hose to VAC

nipple

−

Maintain desoldering nozzle with

cleaning tool

Incorrect status indication by

VAC LEDs

−

Pressure-gauge level not

correctly set

−

Set pressure gauge level in

Special menu 2

No display function
(display OFF)

−

No mains supply voltage

−

Turn on mains power switch

−

Check mains supply voltage

−

Check device fuse

VAC LED red

−

Vacuum system clogged

−

Clean suction nozzle

−

Check filter (13) if yellow, then

replace

−

Clean desoldering tool – replace

filter

−

Check vacuum hose

"Err" display

−

VAC filter clogged

−

Desoldering iron connected

to VAC

−

Hot air tool connected to Vac

−

Replace VAC filter

−

Disconnect desoldering iron

hose

−

Connect hot air tool to AIR

channel


−

Acknowledge error with

┌ 2 ┐button

Advertising