WR 2

19-20

DE

EN

FR

IT

ES

PT

NL

SV

DK

FI

GR

TR

CZ

PL

HU

SK

SL

EE

LV

LT

Replacing the filter
1. Turn the cover cap for "VAC” (14) or "AIR” (15) 45°

counterclockwise and remove.

2. Pull out the contaminated filter and dispose of properly.
3. Insert an original WELLER filter cartridge.

Make sure that the cover seal is properly seated.

4. Insert pressure spring.
5. Abdeckkappe unter leichtem Druck wieder aufsetzen und um

turn clockwise 45°.

10 Error messages and error clearance

Message/symptom

Possible cause

Remedial measures

Display: "- - -

Tool has not been detected

Tool defective

Desoldering iron and hot air

tool are connected

simultaneously

Check connection of tool to

device

Check connected tool

Disconnect one of the tools

No air at HAP

Air hose not or incorrectly

connected

Connect air hose to AIR nipple

No vacuum at desoldering tool − Vacuum hose not or

incorrectly connected

Desoldering nozzle clogged

Connect vacuum hose to VAC

nipple

Maintain desoldering nozzle with

cleaning tool

Incorrect status indication by

VAC LEDs

Pressure-gauge level not

correctly set

Set pressure gauge level in

Special menu 2

No display function
(display OFF)

No mains supply voltage

Turn on mains power switch

Check mains supply voltage

Check device fuse

VAC LED red

Vacuum system clogged

Clean suction nozzle

Check filter (13) if yellow, then

replace

Clean desoldering tool – replace

filter

Check vacuum hose

"Err" display

VAC filter clogged

Desoldering iron connected

to VAC

Hot air tool connected to Vac

Replace VAC filter

Disconnect desoldering iron

hose

Connect hot air tool to AIR

channel


Acknowledge error with

┌ 2 ┐button