6-8

WXP 120

4.2

Technical data

Temperature range

100°C - 450°C (212°F - 850°F)

Tool cable

Silicone rubber, heat resistant

Heating element

Integrated heating wire element

Temperature sensor

Platinum sensor

Heating output

120 W

Voltage (heater)

24 V

Heat-up time

(approx.) 14s (50°C to 380°C)

(120°F to 660°F)

Connection

6 pin connector, polarity protected with lock

Weight

42 g incl. cordless tip

Tip type
Supply unit

XT series
Weller WX stations

5 Commissioning the device

WARNING!

Risk of burns

The soldering tips of soldering irons become very hot during

soldering and desoldering processes.
There is a risk of burns from touching the tips.
Z

Do not touch the hot soldering tips and keep them away from

inflammable objects.

1. Carefully unpack the WXP 120 soldering iron.
2. Place the soldering iron into safety rest WDH 10.
3. Insert the connecting plug (6) into the power supply socket and

lock it by turning it clockwise.

4. Check to make sure that the mains voltage matches the voltage

specified on the rating plate of the WX supply unit.

5. Switch on the supply unit and set the required temperature.
6. If the tool has not reached the required temperature, the status

indicator LED (4) will be lit continuously. Wet the soldering tip

with solder.

6 Replacing the WXP 120 soldering tips

WARNING!

Risk of burns

The soldering tip becomes hot during soldering and desoldering

processes.

There is a risk of burns from touching the soldering tip.
Z

The soldering tool must be switched off and stand at least

3 min. in the safety rest (WDH 10) until the soldering tip has

cooled off. The status indicator LED (4) must be OFF. Only

replace the soldering tips when they are cold.