2 solonox combustion system, Figure 4, Typical combustion process – CAT Titan 250 User Manual
Page 12
 
Turbomachinery Package Specification
Titan
250 Generator Set
For combustion, the gas turbine requires approximately one-fourth of the total air it 
compresses. The excess air is mixed with the combustion products to reduce the gas 
temperature at the turbine first stage-inlet. The cooling air also keeps metal temperatures 
in the combustor and turbine assembly relatively low to ensure a long service life. 
 
Figure 4. Typical Combustion Process
3.1.2
SoLoNOx Combustion System
The Titan 250 incorporates Solar’s proprietary SoLoNOx dry emissions system that 
reduces pollution by limiting the formation of nitrous oxides (NOx), carbon monoxide 
(CO), and unburned hydrocarbons (UHC). This system uses lean premix combustion to 
lower the maximum flame temperature and reduce pollution formation. Solar’s 
engineering staff will work with the customer to meet local permitting emission 
requirements. 
 
Table 1.
Titan 250 Gas Turbine Specifications
Compressor
Type Axial
Flow
Number of Stages
16
Compression Ratio
24:1
Flow (Nominal)
67.3 kg/sec (148 lb/sec)
Speed, Maximum
10,500 rpm
Combustion Chamber
Type Annular 
Ignition Torch 
Number of Fuel Injectors 
14 (SoLoNOx, Low Emissions)
Gas Generator
Type Axial 
Number of Stages 
3
Power Turbine
Type Axial 
Number of Stages 
2
Speed 7000
rpm
Bearings
Radial
5 Tilt Pad with Proximity Probes
Thrust
2 Tilt Pad with Resistance Temperature Device 
Probes 
© 2008 Solar Turbines Incorporated. All rights reserved.
TPS250GS/908 - Preliminary
11