Turbomachinery Package Specification

Titan

250 Generator Set

Figure 2. Typical Titan 250 Generator Set Service Connections (Driver Skid)

Table 1. Package Specifications

Dimensions

Approximate Package Measurements

Height, Unenclosed

3.89 m

(12 ft 9 in.)

Height, Enclosed

4.12 m

(13 ft. 6 in.)

Width (to skid edges)

3.37 m

(11 ft 1 in.)

Width (including lifting bollards)

3.60 m

(11 ft 10 in.)

Length, Engine Skid

10.29 m

(33 ft 9 in.)

Length, Generator Skid

Approximate Package Weights

AC Start Motor Assembly

450 kg

(990 lb)

Gas Turbine Assembly

19 050 kg

(42,000 lb)

Total Driver (unenclosed package, without oil)

49 900 kg

(110,000 lb)

Total Driver (enclosed package, without oil)

57 600 kg

(127,000 lb)

Generator (unenclosed)

Piping and Tubing Thickness

Piping > 76.2 mm (3 in.) Nominal Pipe Size (NPS)

Schedule 40 (Unless Otherwise Specified)

Piping < 50.8 mm (2 in.) NPS

Schedule 80 (Unless Otherwise Specified)

Tubing 3.175 mm (0.125 in.) Nominal Tubing Size
(NTS)

0.889 mm (0.035 in.) Minimum Wall Thickness

Tubing 6.35 mm (0.25 in.) NTS

1.245 mm (0.049 in.) Minimum Wall Thickness

Tubing 12.7 mm (0.50 in.) NTS

1.651 mm (0.065 in.) Minimum Wall Thickness

Tubing 19.05 mm (0.75 in.) NTS

1.651 mm (0.065 in.) Minimum Wall Thickness

Tubing 25.40 mm (1.00 in.) NTS

2.108 mm (0.083 in.) Minimum Wall Thickness

Tubing 31.75 mm (1.25 in.) NTS

2.768 mm (0.109 in.) Minimum Wall Thickness

© 2008 Solar Turbines Incorporated. All rights reserved.