CAT Titan 250 User Manual

Page 13

Advertising
background image

Turbomachinery Package Specification

Titan

250 Generator Set

Construction Materials

Compressor Case

- Forward Section

Nodular Iron

- Aft Section

WC6 Alloy Steel

Combustor Case

410 Stainless Steel

Exhaust Diffuser

Nodular Iron

Accessory Gear Housing

Ductile Iron

Protective Coatings

Compressor Rotor and Stator Blades

Inorganic Aluminum

Nozzles, First and Second Stage

Precious Metal Diffusion Aluminide

Blades, First and Second Stage

Precious Metal Diffusion Aluminide

Approximate Weight

Gas Turbine Assembly

19 050 kg

(42,000 lb)

Performance

Output Power Note (a)

22 370 kW

(30,000 hp)

Heat Rate

9000 kJ/ kW-hr (6360 Btu/ kW-hr)

Exhaust Flow

245 660 kg/hr (541,590 lb/hr)

Exhaust Temperature

465°C

(865°F)

Temperature Monitoring

Turbine T5

(12) Thermocouples

Vibration Monitoring

Turbine Bearing #1

Displacement Probes, X and Y axis

Turbine Bearing #2

Displacement Probes, X and Y axis

Turbine Bearing #3

Displacement Probes, X and Y axis

Turbine Bearing #4

Displacement Probes, X and Y axis

Turbine Bearing #5

Displacement Probes, X and Y axis

Gas Producer Rotor Shaft

Displacement Probe, Axial Position

Power Turbine Rotor Shaft

Displacement Probe, Axial Position

Gas Producer Rotor Shaft

Keyphasor

Power Turbine Rotor Shaft

Keyphasor

Accessory Gearbox

Velocity Pickup

Notes:

(b)

Performance is calculated under the following conditions:
Nominal Rating - ISO at 15°C (59°F), Sea Level
No Inlet/Exhaust Losses
Relative Humidity at 60%
LHV = 31.5 to 43.3 MJ/nm

3

(800 to 1,100 Btu/scf)

© 2008 Solar Turbines Incorporated. All rights reserved.

TPS250GS/908 - Preliminary

12

Advertising