Ground drive fertilizer rate, Johnblue pump rate – Great Plains YP2425F-2470 Material Rate User Manual

Page 42

Advertising
background image

40

YP2425 & YP2425F

Table of Contents

Appendix

Great Plains Manufacturing, Inc.

401-406B

Table of Contents

Appendix

2013-09-23

Ground Drive Fertilizer Rate

One or two CDS-John Blue

®

ground drive pumps (on

newer planters), or two Hypro ground drive pumps (on
older planters), customarily supply a Type 2 boom on the
planter. Rate setting is different for each pump type.

JohnBlue Pump Rate

Refer to Figure 15 and Figure 16

One piston pump

generally suffices for “starter”

application rates. Two piston pumps may be required for
higher rates.

Coarse rate is set by a single “driving” sprocket

on the

ground drive assembly. Fine rate is set on a dial (setting
hub)

at the pump, using a tool supplied with the pump.

Rate settings may be established in any of three ways:

• the table on the next page,

• the slide chart provided with the pump, or;

• a calculator on the JohnBlue internet web site

(

www.cds-johnblue.com

)

1.

Check plumbing setup. See “Setting Relief Valve
and “Strainer” in the Operator Manual.

2.

Determine Driving sprocket (15T or 47T) required
from table, slide chart or web calculator. If this
sprocket is already installed on driven shaft, skip to
step 7. Otherwise, to change sprocket, continue with
step 3.

3.

Remove knob

and guard

. Loosen idler

, and

remove chain

from lower jackshaft

.

4.

Select the new sprocket from the storage shaft

.

Remove the pins, and exchange sprockets. Store the
previous sprocket on the storage shaft.

5.

Remount the chain

. Re-engage idler

, tightening

so that the longest span of the chain has

1

4

in (6mm)

of slack.

6.

Remount guard

and secure with knob

.

Refer to Figure 16

7.

Using the box-wrench end of the JohnBlue
115681-01 tool, loosen the setting pointer nut

.

8.

Use the other end of the tool to rotate the dial

to

the setting determined by table, slide chart or web.

9.

Re-tighten pointer nut.

Figure 15

CDS-John Blue

®

Pump

28416

Contact wheel and chain system operate whenever the
planter is lowered and in motion. If planting without
fertilizing, the pump must not be allowed to run dry.
Disconnect chain or remove sprocket.

4

3

2

5

6

7

8

9

2

3

4

5

6

7

8

3

9

Figure 16

Pump Dial

26155

4

9

8

7

6

5

9

4

Advertising
This manual is related to the following products: